R407C Refrigerant Price per Pound R407C is a non-ozone depleting refrigerant that contributes somewhat to global warming, even though it is still a preferable option to R22 coolant. On average, Refrigerant 407C price ranges between $4 and $7 per pound.

Does 407C cool as well as R22?

It is found after the careful observation that R22 performs somewhat better than R407C in many aspects i.e. COP, Cooling Capacity, Energy Consumption, and Exergetic Analysis but retrofitting point of view, it is best suitable refrigerant and R410A is suitable for new design.

Can R407C be used to replace R22?

The best replacement for R-22 Freon is usually R-407c. It has a very low loss in capacity (0 – 5%) relative to R-22 and is less expensive than many other R-22 replacement refrigerants.

What does 407C refrigerant replace?

R-407C cylinders are colored burnt orange. This refrigerant is intended as a replacement for R-22. R-22 production will be phased out by 2020 as per the Montreal Protocol.

How do you charge 407C?

R-407C should always be charged as a liquid. Due to its zeotropic nature, it will fractionate if charged as a vapor, causing poor system performance — and, possibly, system failure.

Which is better R-407C vs R410A?

While R-410A’s operating pressure at high ambient temperatures is inarguably higher than that of R-407C, at Super Radiator Coils, we’re able to produce UL-listed solutions that use R-410A for up to 700 PSIG, making it a completely safe and effective refrigerant for warmer climates.

Is R407C banned?

The higher GWP refrigerants R134a, R410A and R407C are amongst a list of over 25 refrigerants deemed unacceptable for use in positive displacement and centrifugal chillers from January 1, 2024. … The same two refrigerants and 19 others are being listed as unacceptable in new cold storage warehouses from January 1, 2023.

What is the difference between R22 and R407C?

R407C has 6.60 % more pressure ratio than R22. Lower pressure ratio was suggested for higher compressor efficiency. Joudi et al. (11) showed that the average compression ratio of R407C is higher by 3.7% & 5.6% for 1 TR and 2 TR system respectively than that of R22.

What is the difference between r407a and R407C?

Freon™ 407C exhibits similar performance to HCFC-22 at air conditioning conditions, while Freon™ 407A exhibits similar performance to R-404A with lower capacity at low and medium temperature refrigeration conditions.

What pressure does 407C run at?

If this is so always evaporating above zero, 4 or 5 deg celcius, R407c will have a low pressure (suction ) of about 50 psi. and a high pressure ( discharge ) of about 280 psi, which is about 55 deg celcius, cooling cycle.

How much R22 is in a 3 ton unit?

The amount of cooling for your system can be estimated in the range of 2 to 4 pounds per ton. The 3-ton AC or Heat Pump with a 35 foot lineset will need a total of about 12 pounds of refrigerant.

What is R407C refrigerant used for?

R-407C is a non-azeotropic mixed refrigerant composed of the three ingredients R-32, R-125, and R-134a, and was developed as a substitute refrigerant for R-22, used in applications such as air conditioning equipment and chiller equipment for medium temperature ranges.

Can I buy R407C?

Each container is a new, factory sealed, disposable container with guaranteed quality and value. Stop by our online store, send us an email, or give us a call to get the best deal in town on refrigerant products such as R407C and start saving today.

Do you charge 407C as a liquid?

8. Charge System with Freon™ 407C. This refrigerant should be removed from the cylinder as a liquid. … Once liquid is removed from the cylinder, the refrigerant can be charged to the system as liquid or vapor as required.

Can you top up R407C?

Re: R407c top up. When R407C leaks, you can end up with a refrigrant mix with operating pressures similar to R410A. It is not practical to determine the remaining refrigerant and is usually best to reclaim and start again with new refrigerant.

What is the difference between 407C and 410A?

Freon™ 407C exhibits similar performance to HCFC-22, while Freon™ 410A gives significantly higher pressure and refrigeration capacity.

Can you use R407C in a R410A system?

Mainly R407c but also can provide R410a, R404a (for very low temperatures), or R134a for high ambient temperatures (up to 113 F) or high pre-run water temperatures (to 95 F).

Why refrigerants such as R407C and R410A are replacing R22?

The high operating pressures can also restrict the use of R410A to smaller systems, especially on water cooled systems. Both R407C and R410A are less harmful to the environment than R22 and they offer equivalent performance and higher capacity alternatives to R22.

IS 407C flammable?

R-407C is not flammable at ambient temperatures and atmospheric pressure. However, this material will become combustible when mixed with air under pressure and exposed to strong ignition sources.

Is R407C CFC free?

Introduction and Features of R407C R407C is a kind of CFC-free refrigerant that does not deplete the ozone layer. With similar compressor capacity, system temperature and pressure to R22, it is considered as a direct substitute with features as follows: The refrigerant should be liquefied when added into the system.

Can I replace R407C with R134A?

Yes. With air-conditioning systems that are similarly optimized, the compressor discharge temperature in an R134a system shall be 18–30 °F (10–17 °C) lower than that in an R407C system.

Can I use R32 instead of R22?

Relatively, R32 has very low GWP compared to R22, and therefore leading R32 to be a potential substitute for R22. … The liquid density ratio between R32 and R22 at 0oC is 0.82. As a result, theoretically, for drop-in 100% from R22 with R32, the refrigerant charge amount of R32 is 82% of R22 (by mass).